Description
Spec Sheet Install Manual
The GM40AV Time Switch is a universal, electromechanical time switch designed for general purpose residential and commercial applications. The robust 40 A time switch automatically detects the input voltage without the use of a DIP switch or selector pins. The time switch automatically selects any voltage between 120-277 VAC. The mechanism is mounted in a compact UL Type 3R outdoor enclosure and can also be easily retrofitted into other Intermatic enclosure types. The time switch features a DPDT switching configuration standard (i.e. two normally open and two normally closed contacts).
Features:
- Autovoltage selection 120 VAC-277 VAC
- Captive trippers - trippers cannot be lost
- 40 A rating
- Self-recharging battery backup, "Q" models feature 72-hour carry-over
- Power and status LED indicators
- 24-Hour or 7-day models available
- Up to 48 ON/OFF operations per 24-hour period or 42 ON/OFF operations per week on "W" models
- DPDT switching configuration standard (2 NO and 2 NC Contacts)
- Manual three-way ON/OFF/AUTO override switch
- Easy-to-read clock face
Applications:
-
Aeration
-
Air Movement & Ventilation
-
Generator Exercising
-
Refrigeration Merchandiser
-
Septic Treatment
Specifications:
Backup Type | 72-hour Carry-over, Battery, Self-recharging | Input Voltage Range(s) | 120-277 VAC, 50/60 Hz |
Maximum ON/OFF Operations | 42 | Operation Mode | 7-day |
Switch Type | DPDT | Enclosure Type | Indoor/outdoor type 3R plastic |
Has Real-time Clock Face | Yes | Minimum ON/OFF Times | 2-Hours |
Maximum ON/OFF Times | 2 hours | Mechanism Type | Electromechanical |
Resistive (NO) | 40 A, 120-277 VAC | Warranty Period | 1-Year limited |
Wiring Option | Screw box lug | Backup Protection Time | 72 Hours |
Battery Service Type | Rechargeable | Battery Type | Rechargeable |
Category | Timer Controls Web | Electrical Life | 50,000 operations at full load |
Has Captive Trippers | Yes | Has Override Switch | Yes |
Magnetic Ballast (NC) Range(s) | 10 A, 277 VAC | Magnetic Ballast (NO) Range(s) | 30 A, 120 VAC; 20 A, 277 VAC |
Motor (NC) | 1 HP, 12 FLA, 30 LRA @120 VAC, 2 HP, 10 FLA, 30 LRA @240 VAC | Motor (NO) | 1 HP, 16 FLA, 90 LRA @ 120 VAC, 2 HP, 12 FLA, 52 LRA @ 208-277 VAC |
Motor Load Ratings NC Ranges | 1 HP, 12 FLA, 30 LRA @ 120 VAC; 2 HP, 10 FLA, 30 LRA @ 240 VAC | Motor Load Ratings NO Ranges | 1 HP, 16 FLA, 90 LRA @120 VAC; 2 HP, 12 FLA, 52 LRA @ 208-277 VAC |
Number of Trippers Included | 84 | Operating Humidity | 0-95% RH, Non-condensing |
Pilot Duty (NO) | 300 VA, 120 VAC, 300 VA, 120 VAC, 50 Hz, 300 VA, 208 VAC, 300 VA, 208 VAC, 50 Hz, 300 VA, 240 VAC, 300 VA, 240 VAC, 50 Hz | Pilot Duty (NO) Range(s) | 300 VA, 120-240 VAC |
Pilot Duty Load Ratings Ranges | 300 VA, 120-240 VAC | Power consumption (V) | 1 VA |
Resistive (NC) | 30 A, 120 VAC, 50 Hz, 30 A, 120 VAC, 60 Hz, 30 A, 208 VAC, 50 Hz, 30 A, 208 VAC, 60 Hz, 30 A, 240 VAC, 50 Hz, 30 A, 240 VAC, 60 Hz, 30 A, 277 VAC, 50Hz, 30 A, 277 VAC, 60Hz | Resistive (NC) Range(s) | 30 A, 120-277 VAC |
Resistive (NO) Range(s) | 40 A, 120-277 VAC | Tungsten (NC) Load Ratings | 2 A, 120 VAC |
Tungsten (NO) Load Ratings | 15 A, 120 VAC | Voltage Selection Type | Auto Voltage |
Wire Size Max | #8 AWG | Operating Temperature Max (°C) | 55 |
Operating Temperature Max (°F) | 131 | Operating Temperature Min (°C) | -40 |
Operating Temperature Min (°F) | -40 | Product Depth (in) | 3 |
Product Depth (mm) | 7.62 | Product Height (in) | 8 7/8 |
Product Height (mm) | 22.56 | Product Width (in) | 6 39/64 |
Product Width (mm) | 16.79 | Unit Carton Height (in) | 9.125 |
Unit Carton Length (in) | 6.75 | Unit Carton Weight (lb) | 1.896 |
Unit Carton Width (in) | 3 |